Search results for "chemical detection"

showing 10 items of 15 documents

Electrochemical detection of nitric oxide in plant cell suspensions

2016

SPE IPM UB; Nitric oxide is a hydrophobic radical acting as a physiological mediator in plants. Because of its unique properties, the detection of NO in plant tissues and cell suspensions remains a challenge. For this purpose, several techniques are used, each having certain advantages and limitations such as interferences with other species, questionable sensitivity, and/or selectivity or ex situ measurement. Here we describe a very attractive approach for tracking NO in plant cell suspensions using a NO-sensitive homemade platinum/iridium-based electrochemical microsensor. This method constitutes the absolute real-time proof of the production of free NO in physiological conditions.

0106 biological sciences0301 basic medicinehome-made electrodeChemistry[SDV]Life Sciences [q-bio]fungichemistry.chemical_elementElectrochemical detectionPlant cellElectrochemistry01 natural sciencesNitric oxide03 medical and health scienceschemistry.chemical_compound030104 developmental biologyChemical engineeringnitric oxideplant cell suspensionselectrochemical detection[SDE]Environmental Sciences[SDV.BV]Life Sciences [q-bio]/Vegetal BiologyIridiumPlatinumSelectivity010606 plant biology & botany
researchProduct

Real-time electrochemical detection of extracellular nitric oxide in tobacco cells exposed to cryptogein, an elicitor of defence responses

2008

International audience; It was previously reported that cryptogein, an elicitor of defence responses, induces an intracellular production of nitric oxide (NO) in tobacco. Here, the possibility was explored that cryptogein might also trigger an increase of NO extracellular content through two distinct approaches, an indirect method using the NO probe 4,5-diaminofluorescein (DAF-2) and an electrochemical method involving a chemically modified microelectrode probing free NO in biological media. While the chemical nature of DAF-2-reactive compound(s) is still uncertain, the electrochemical modified microelectrodes provide real-time evidence that cryptogein induces an increase of extracellular N…

0106 biological sciencesPhysiologyPLANT DEFENSE RESPONSEPlant ScienceElectrochemical detectionBiology01 natural sciencesDIETHYLAMINE NONOATENitric oxide[SDV.BV.BOT] Life Sciences [q-bio]/Vegetal Biology/BotanicsFungal Proteins03 medical and health scienceschemistry.chemical_compoundTobaccoBotanyElectrochemistryExtracellularCells Cultured030304 developmental biology0303 health sciencesFungal proteinAlgal Proteins[SDV.BV.BOT]Life Sciences [q-bio]/Vegetal Biology/BotanicsResearch PapersElectrochemical gas sensorElicitorMicroelectrodechemistryBiophysicsDIAMINOFLUORESCEINplant defence responsesIntracellularELECTROCHEMICAL SENSORNITRIC OXIDE010606 plant biology & botany
researchProduct

Chemical host detection and differential attraction in a parasitic pea crab infecting two echinoids

2011

Mechanisms of host detection and host choice are important for mobile parasites or symbionts that frequently move among host individuals. The parasitic pea crab Dissodactylus primitivus is an ectoparasite exploiting asymmetrically two spatangoid echinoid hosts, Meoma ventricosa and Plagiobrissus grandis. The entire life cycle takes place on M. ventricosa, while only adults colonize P. grandis, the host where female's fecundity is the greatest. Dissodactylus primitivus frequently exhibits host-switching, a behaviour that raises the question of host detection. To test if adult crabs are able to detect potential hosts and are attracted to the host where their fitness is greater, crab olfactory…

0106 biological sciences[ SDV.MP.PAR ] Life Sciences [q-bio]/Microbiology and Parasitology/Parasitologyanimal structuresChemical detectionZoologyAquatic ScienceGeneralist and specialist species010603 evolutionary biology01 natural sciencesMeoma ventricosaPea crab[ SDV.EE.IEO ] Life Sciences [q-bio]/Ecology environment/Symbiosis[SDV.MP.PAR]Life Sciences [q-bio]/Microbiology and Parasitology/ParasitologyEcology Evolution Behavior and SystematicsDissodactylus primitivus[ SDE.BE ] Environmental Sciences/Biodiversity and EcologyPea crabbiologyDecapodaEcology010604 marine biology & hydrobiologyfood and beveragesImprintingbiology.organism_classificationFecundityAttractionCrustaceanParasiteHabitatHost-switchingEchinoidea [Sea urchins]Echinoid[SDE.BE]Environmental Sciences/Biodiversity and Ecology[SDV.EE.IEO]Life Sciences [q-bio]/Ecology environment/Symbiosis
researchProduct

Development of an Analytical Assay for Electrochemical Detection and Quantification of Protein-Bound 3-Nitrotyrosine in Biological Samples and Compar…

2020

Reactive oxygen and nitrogen species (RONS) cause oxidative damage, which is associated with endothelial dysfunction and cardiovascular disease, but may also contribute to redox signaling. Therefore, their precise detection is important for the evaluation of disease mechanisms. Here, we compared three different methods for the detection of 3-nitrotyrosine (3-NT), a marker of nitro-oxidative stress, in biological samples. Nitrated proteins were generated by incubation with peroxynitrite or 3-morpholino sydnonimine (Sin-1) and subjected to total hydrolysis using pronase, a mixture of different proteases. The 3-NT was then separated by high performance liquid chromatography (HPLC) and quantifi…

0301 basic medicinePhysiologyClinical BiochemistryDot blotmitochondrial superoxidePronase030204 cardiovascular system & hematologymedicine.disease_causeBiochemistryHigh-performance liquid chromatographyArticleperoxynitritePeroxynitrite03 medical and health sciences0302 clinical medicineProtein-bound 3-nitrotyrosinemedicineoxidative stressBovine serum albuminMolecular Biologychemistry.chemical_classificationDetection limitReactive oxygen speciesChromatographyHPLC with electrochemical detectionbiologylcsh:RM1-950Cell Biology3. Good health030104 developmental biologylcsh:Therapeutics. PharmacologychemistryOxidative stressbiology.proteinprotein-bound 3-nitrotyrosineOxidative stressEx vivoMitochondrial superoxide
researchProduct

Development and validation of an analytical assay for electrochemical detection and quantification of protein‐bound 3‐nitrotyrosine in biological sam…

2020

3-nitrotyrosineChromatographybiologyChemistryGeneticsbiology.proteinElectrochemical detectionAntibodyMolecular BiologyBiochemistryBiotechnologyThe FASEB Journal
researchProduct

The emerging role of 3D printing in the fabrication of detection systems

2021

Abstract 3D printing is fast evolving as an additive manufacturing technique that has been adopted in (bio)analytical science because of the ample variety of materials and technologies currently available for highly affordable prototyping. This review focuses on the unique characteristics of 3D printing for manufacturing of optical and electrochemical detection systems, and sampling interfaces for analytical purposes using fused deposition modelling, vat polymerization (stereolithography and digital light processing) and photopolymer inkjet printing. The majority of works surveyed within the time span of mid-2018 to mid-2020 encompassed the fabrication of several components of the detection…

3d printedFabricationEmerging technologiesComputer sciencebusiness.industry010401 analytical chemistry3D printingElectrochemical detection01 natural sciences0104 chemical sciencesAnalytical Chemistrylaw.inventionlawSystems engineeringDigital Light ProcessingbusinessSpectroscopyStereolithographyInkjet printingTrAC Trends in Analytical Chemistry
researchProduct

Simultaneous determination of four 5-hydroxy polymethoxyflavones by reversed-phase high performance liquid chromatography with electrochemical detect…

2009

Accumulating evidence has suggested the potential health-promoting effects of 5-hydroxy polymethoxyflavones (5-OH-PMFs) naturally existing in citrus genus. However, research efforts are hampered by the lack of reliable and sensitive methods for their determination in plant materials and biological samples. Using reversed-phase high performance liquid chromatography (HPLC) equipped with electrochemical (EC) detection, we have developed a fast and highly sensitive method for quantification of four 5-OH-PMFs, namely 5-hydroxy-6,7,8,3',4'-pentamethoxyflavone, 5-hydroxy-3,6,7,8,3',4'-hexamethoxyflavone, 5-hydroxy-6,7,4'-trimethoxyflavone, and 5-hydroxy-6,7,8,4'-tetramethoxyflavone. The method wa…

FlavonoidsDetection limitOrange juicechemistry.chemical_classificationCitrusAccuracy and precisionChromatographyOrganic ChemistryFlavonoidReproducibility of ResultsElectrochemical TechniquesGeneral MedicineReversed-phase chromatographyElectrochemical detectionHydrogen-Ion ConcentrationFlavonesSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryBeverageschemistryLinear ModelsChromatography High Pressure LiquidCitrus × sinensisJournal of Chromatography A
researchProduct

Identification of 5,6,7,8-tetrahydropterin and 5,6,7,8-tetrahydrobiopterin in Drosophila melanogaster.

1988

Summary Using reversed-phase high-performance liquid chromatography with electrochemical detection we have demonstrated the occurrence of 5,6,7,8-tetrahydropterin and 5,6,7,8-tetrahydrobiopterin in Drosophila melanogaster . The former is the first time that has been detected in vivo . The identification has been based on the retention times, hydrodinamic voltagrams and the differential concentration in three strains of Drosophila melanogaster . Compared to the wild type, the Punch 2 mutant has diminished levels of both pteridines, whereas Henna-recessive 3 lacks completely tetrahydropterin and has increased levels of tetrahydrobiopterin, as expected according to their biochemical lesions.

GeneticsbiologyMutantBiophysicsWild typeCell BiologyElectrochemical detectionTetrahydrobiopterinbiology.organism_classificationKidneyBiochemistryHigh-performance liquid chromatographyBiopterinPterinsRatsDrosophila melanogasterBiochemistryIn vivomedicineAnimalsDrosophila melanogasterMolecular BiologyChromatography High Pressure Liquidmedicine.drugBiochemical and biophysical research communications
researchProduct

Selective and Sensitive Chromofluorogenic Detection of the Sulfite Anion in Water Using Hydrophobic Hybrid Organic-Inorganic Silica Nanoparticles

2013

[EN] In water and wine: Chromofluorogenic detection of the sulfite anion in pure water was accomplished by using a new hybrid organic-inorganic material that contained a probe entrapped in hydrophobic biomimetic cavities. This material was used for the detection of sulfite in red wine. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

INGENIERIA DE LA CONSTRUCCIONOrganic-inorganic hybrid materialsInorganic chemistryWineSO2Electrochemical detectionMesoporous nanoparticlesCatalysisSilica nanoparticleschemistry.chemical_compoundQUIMICA ORGANICASulfiteQUIMICA ANALITICAOrganic inorganicAsthmatic-patientsElectrochemical detectionAsthmatic patientSpectrophotometric methodSensorsFood analysisBisulfiteQUIMICA INORGANICAGeneral ChemistryGeneral MedicineDerivatizationFoodschemistrySulfiteRatiometric fluorescent-probeCapillary electrophoretic determinationNuclear chemistryAngewandte Chemie
researchProduct

Impulse interval-dependent effect of sympathetic nerve stimulation on evoked acetylcholine release from the rabbit perfused atria preparation.

1995

The aim of the present study was to explore possible prejunctional effects mediated by impulse activity of sympathetic terminals on evoked acetylcholine release in an organ innervated by the autonomic ground plexus. Rabbit atria were isolated with the extrinsic right vagus and sympathetic nerves intact and perfused with Tyrode solution. Acetylcholine overflow was determined after labelling of the transmitter stores with [14C]choline and fractionation of the radioactivity on cation exchange columns. The overflow of endogenous noradrenaline was measured by HPLC and electrochemical detection. The vagus nerve was stimulated at 2 Hz for 3 min four times at intervals of 10 min. During the second …

Malemedicine.medical_specialtySympathetic Nervous SystemSympathetic nerveStimulationEndogenyElectrochemical detectionImpulse (physics)In Vitro TechniquesReceptors PresynapticCholinechemistry.chemical_compoundInternal medicinemedicineElectrochemistryCholineAnimalsChromatography High Pressure LiquidPharmacologyPlexusGanglia SympatheticChemistryMyocardiumHeartVagus NerveGeneral MedicineMyocardial ContractionAcetylcholineElectric StimulationPerfusionEndocrinologycardiovascular systemFemaleRabbitsAcetylcholinemedicine.drugNaunyn-Schmiedeberg's archives of pharmacology
researchProduct